CVE-2020-8478
Estado: ModificadaBaja (3.3)—
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
- Puntuación base: 3.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.34%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-264
- CWE-74
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-8478",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.3,
"attackVector": "LOCAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@ch.abb.com",
"affectedData": [
{
"vendor": "ABB",
"product": "OPC Server for AC 800M",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"vendor": "ABB",
"product": "MMS Server for AC 800M",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"vendor": "ABB",
"product": "Base Software for SoftControl",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
]
}
],
"published": "2020-04-29T02:15:11.763",
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@ch.abb.com"
},
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
},
{
"lang": "es",
"value": "Una protección insuficiente de las funciones de comunicación entre procesos en los productos OPC Server para AC 800M, MMS Server para AC 800M y Base Software para SoftControl (todas las versiones publicadas) de ABB System 800xA, permite a un atacante autenticado en el sistema local inyectar datos, afectando la visualización en línea de los datos del tiempo de ejecución que se muestran en Control Builder."
}
],
"lastModified": "2026-06-17T03:26:26.707",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:mms_server:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "296927D5-AF68-488F-A606-818ACD253B75"
},
{
"criteria": "cpe:2.3:a:abb:opc_server:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9BF1B4E-225B-4A2C-A5EB-996A6CCA1F79"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:ac800m:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "18F5825D-A99A-4109-A08F-114C7D6D3FC3"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*",
"vulnerable": true,
"matchCriteriaId": "D30E09D7-4C4D-459F-95DC-3B9FA341E5A4"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com"
}