CVE-2020-8466
Estado: ModificadaCrítica (9.8)—
A command injection vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2, with the improved password hashing method enabled, could allow an unauthenticated attacker to execute certain commands by providing a manipulated password.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 64%
- Percentil entre todas las CVEs puntuadas: 99
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
- https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/
- https://success.trendmicro.com/solution/000283077
- https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/
- https://success.trendmicro.com/solution/000283077
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-8466",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "security@trendmicro.com",
"affectedData": [
{
"vendor": "Trend Micro",
"product": "Trend Micro InterScan Web Security Virtual Appliance",
"versions": [
{
"status": "affected",
"version": "6.5 SP2"
}
]
}
]
}
],
"published": "2020-12-17T21:15:13.147",
"references": [
{
"url": "https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "security@trendmicro.com"
},
{
"url": "https://success.trendmicro.com/solution/000283077",
"tags": [
"Vendor Advisory"
],
"source": "security@trendmicro.com"
},
{
"url": "https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://success.trendmicro.com/solution/000283077",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2, with the improved password hashing method enabled, could allow an unauthenticated attacker to execute certain commands by providing a manipulated password."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyección de comandos en Trend Micro InterScan Web Security Virtual Appliance versión 6.5 SP2, con el método habilitado de hashing de contraseña mejorado, podría permitir a un atacante no autenticado ejecutar determinados comandos al proporcionar una contraseña manipulada"
}
],
"lastModified": "2026-06-17T03:26:25.143",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trendmicro:interscan_web_security_virtual_appliance:6.5:sp2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "778D5B34-395F-48EF-9E7D-B8FD11FEBE7E"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@trendmicro.com"
}