CVE-2020-7536
Status: ModifiedHigh (7.5)—
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Base score: 7.5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 1.17%
- Percentile among all scored CVEs: 66
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (10)
Schneider-electric — Bmxnoe0100 FirmwareSchneider-electric — Bmxnoe0110 FirmwareSchneider-electric — Bmxnor0200h FirmwareSchneider-electric — Modicon M340 Bmxp341000 FirmwareSchneider-electric — Modicon M340 Bmxp342000 FirmwareSchneider-electric — Modicon M340 Bmxp3420102 FirmwareSchneider-electric — Modicon M340 Bmxp3420102cl FirmwareSchneider-electric — Modicon M340 Bmxp342020 FirmwareSchneider-electric — Modicon M340 Bmxp3420302 FirmwareSchneider-electric — Modicon M340 Bmxp3420302cl Firmware
CWEs
- CWE-754
References
Raw JSON (NVD)
Show
{
"id": "CVE-2020-7536",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Modicon M340 CPUs (BMXP34* versions prior to V3.30) and Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4, BMXNOE0110 (H) versions prior to V6.6, and BMXNOR0200H all versions)",
"versions": [
{
"status": "affected",
"version": "Modicon M340 CPUs (BMXP34* versions prior to V3.30) and Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4, BMXNOE0110 (H) versions prior to V6.6, and BMXNOR0200H all versions)"
}
]
}
]
}
],
"published": "2020-12-11T01:15:12.190",
"references": [
{
"url": "https://security.cse.iitk.ac.in/responsible-disclosure",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-07/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://security.cse.iitk.ac.in/responsible-disclosure",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-07/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-754"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP."
},
{
"lang": "es",
"value": "Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M340 CPUs (BMXP34* versiones anteriores a V3.30) Módulos Modicon M340 Communication Ethernet (BMXNOE0100 (H) versiones anteriores a V3.4, BMXNOE0110 (H) versiones anteriores a V6.6, BMXNOR0200H todas las versiones), lo que podría causar que el dispositivo no sea accesible cuando se modifican los parámetros de red a través de SNMP"
}
],
"lastModified": "2026-06-17T03:24:57.813",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C440362A-7E0E-497C-B275-409E9B57D8A2",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "178D2338-E48E-493C-992F-337AACE794DE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B6ACCC66-4075-4EE9-A6BA-01EF7529C568",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6D150239-27E2-4CBE-A931-5107C15E362F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD031F4E-9F3C-4035-AFB8-B7442F1B2475",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "98212CF5-BCF4-4A55-B62A-484569687B4E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1C1D1498-1069-4080-8EB4-3BA6C0DC2CEA",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102cl:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D30336F0-EDCF-486C-B52E-D0C53BCDFC65"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5481772-5E18-4985-A5E5-F7223B52A90B",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1A83CF92-F35F-416F-B571-CA5600BF671F",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "354968F7-C41B-4C21-8E47-81DC07DF0EA5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8E506AD9-C302-4D41-B971-46DE19AF83FB",
"versionEndExcluding": "3.30"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302cl:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "32091F91-9397-4506-8801-C68B9E8B60F0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4C045040-20CA-488D-A36D-A433754A33E8",
"versionEndExcluding": "3.4"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "80FC6FF2-D662-4A57-AAA6-BC04351DC779"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1A33A381-6772-4137-A677-5F73EA398FF6",
"versionEndExcluding": "6.6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "98F3B055-8919-4E09-9827-288F0A03DAFF"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AECF5778-C5F5-4789-BD3D-793B35DDDBDF"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}