« Volver al listado

CVE-2020-7350

Estado: ModificadaAlta (7.8)—

Rapid7 Metasploit Framework versions before 5.0.85 suffers from an instance of CWE-78: OS Command Injection, wherein the libnotify plugin accepts untrusted user-supplied data via a remote computer's hostname or service name. An attacker can create a specially-crafted hostname or service name to be imported by Metasploit from a variety of sources and trigger a command injection on the operator's terminal. Note, only the Metasploit Framework and products that expose the plugin system is susceptible to this issue -- notably, this does not include Rapid7 Metasploit Pro. Also note, this vulnerability cannot be triggered through a normal scan operation -- the attacker would have to supply a file that is processed with the db_import command.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-7350",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cve@rapid7.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@rapid7.com",
      "affectedData": [
        {
          "vendor": "Rapid7",
          "product": "Metasploit Framework",
          "versions": [
            {
              "status": "affected",
              "version": "5.0.85",
              "lessThan": "5.0.85",
              "versionType": "custom"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-04-22T22:15:12.450",
  "references": [
    {
      "url": "https://github.com/rapid7/metasploit-framework/issues/13026",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@rapid7.com"
    },
    {
      "url": "https://github.com/rapid7/metasploit-framework/issues/13026",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cve@rapid7.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rapid7 Metasploit Framework versions before 5.0.85 suffers from an instance of CWE-78: OS Command Injection, wherein the libnotify plugin accepts untrusted user-supplied data via a remote computer's hostname or service name. An attacker can create a specially-crafted hostname or service name to be imported by Metasploit from a variety of sources and trigger a command injection on the operator's terminal. Note, only the Metasploit Framework and products that expose the plugin system is susceptible to this issue -- notably, this does not include Rapid7 Metasploit Pro. Also note, this vulnerability cannot be triggered through a normal scan operation -- the attacker would have to supply a file that is processed with the db_import command."
    },
    {
      "lang": "es",
      "value": "Las versiones de Rapid7 Metasploit Framework anteriores a la versión  5.0.85 sufren de una instancia de CWE-78: Inyección de comandos del sistema operativo, en la que el complemento libnotify acepta datos no seguros  proporcionados por el usuario a través del nombre de host o nombre de servicio de un ordenador remoto. Un atacante puede crear un nombre de host o nombre de servicio especialmente diseñado para ser importado por Metasploit desde una variedad de fuentes y desencadenar una inyección de comando en la terminal del operador. Tenga en cuenta que solo Metasploit Framework y los productos que exponen el sistema de complementos son susceptibles a este problema; en particular, esto no incluye Rapid7 Metasploit Pro. También tenga en cuenta que esta vulnerabilidad no puede activarse mediante una operación de exploración normal: el atacante tendría que proporcionar un archivo que se procese con el comando db_import."
    }
  ],
  "lastModified": "2026-06-17T03:24:44.947",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rapid7:metasploit:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AE42CAE4-4C47-40EC-AC83-D6EE17824B2B",
              "versionEndExcluding": "5.0.85"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@rapid7.com"
}