Estado: ModificadaCrítica (10)—

In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (9)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-6962",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 10,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors",
          "versions": [
            {
              "status": "affected",
              "version": "ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server,v4.2 & prior,Clinical Information Center,v4.X & 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-01-24T17:15:13.127",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf",
      "tags": [
        "Product"
      ],
      "source": "nvd@nist.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution."
    },
    {
      "lang": "es",
      "value": "En ApexPro Telemetry Server, Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Telemetry Server Versión 4.3, CARESCAPE Central Station (CSCS) Versiones 1.X, CARESCAPE Central Station (CSCS) Versiones 2.X, B450 Versión 2.X, B650 Versión 1.X, B650 Versión 2.X, B850 Versión 1.X, B850 Versión 2.X, se presenta una vulnerabilidad de comprobación de entrada en la utilidad de configuración del sistema basada en web que podría permitir a un atacante obtener una ejecución arbitraria de código remoto."
    }
  ],
  "lastModified": "2026-06-17T03:24:01.457",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59",
              "versionEndIncluding": "4.2"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:4.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6A7CD125-E50C-4A1E-BF2B-318162D634CC"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_b450_monitor_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C9607F33-BAC9-4F45-8685-9091CBBF4336"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_b450_monitor:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "FDF68D5F-E436-492A-965E-0E9E254ACBFF"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CF1DCCAF-A4E6-484B-953D-9352C85DE894"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_b650_monitor_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D9A5B8CF-5214-4056-87CD-CD1F98142BD6"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_b650_monitor:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3B149BFB-BB31-4FFC-BC4D-299AB326136D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BDE014C2-9814-4137-9270-9B2AB55D3ABF"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_b850_monitor_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AD10A852-3E11-4436-B771-53A9947A355E"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_b850_monitor:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7B8CA355-421A-44DE-A7EA-0BC0ACFDD697"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9304DE75-4BCB-4C13-97D5-547195441591"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "43F897B5-1F21-466D-A99C-2E6A98E93FFA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610",
              "versionEndIncluding": "4.2"
            },
            {
              "criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:4.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "13F7A4D6-2B11-4B74-A645-8AB1ADDBBC95"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}