CVE-2020-35808
Status: ModifiedMedium (4.8)—
Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
- Base score: 4.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.52%
- Percentile among all scored CVEs: 42
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (7)
CWEs
- CWE-79
References
Raw JSON (NVD)
Show
{
"id": "CVE-2020-35808",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-12-30T00:15:14.863",
"references": [
{
"url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://kb.netgear.com/000062708/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-Range-Extenders-PSV-2018-0158",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects D6100 before 1.0.0.63, DM200 before 1.0.0.61, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN3000RPv2 before 1.0.0.68, and WNR2000v5 before 1.0.0.66."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR están afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D6100 versiones anteriores a 1.0.0.63, DM200 versiones anteriores a 1.0.0.61, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, WN3000RPv2 versiones anteriores a 1.0.0.68 y WNR2000v5 versiones anteriores a 1.0.0.66."
}
],
"lastModified": "2026-06-17T03:14:21.390",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A",
"versionEndExcluding": "1.0.0.63"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6B27650A-B7FE-41E4-8231-9283CC7B8349",
"versionEndExcluding": "1.0.0.61"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76",
"versionEndExcluding": "1.0.2.52"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D",
"versionEndExcluding": "1.0.4.12"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E",
"versionEndExcluding": "1.0.4.12"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wn3000rpv2_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0F20A1B5-DBD0-445F-AB0D-30212439FFD4",
"versionEndExcluding": "1.0.0.68"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wn3000rpv2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "50BC8FA2-F9D5-4286-97DD-BD2A55EA234D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000v5_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D275B1AC-7E46-4892-9ACB-DEB53543E0B5",
"versionEndExcluding": "1.0.0.66"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000v5:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "671EC923-DC84-47D6-B943-0F7DA8168334"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}