CVE-2020-35801
Estado: ModificadaAlta (7.3)—
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.71%
- Percentil entre todas las CVEs puntuadas: 76
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- NVD-CWE-noinfo
Referencias
- https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376
- https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/
- https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376
- https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-35801",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 5.5,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-12-30T00:15:14.457",
"references": [
{
"url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
"tags": [
"Not Applicable"
],
"source": "cve@mitre.org"
},
{
"url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
"tags": [
"Not Applicable"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR están afectados por una configuración incorrecta de los ajustes de seguridad. Esto afecta a JGS516PE versiones anteriores a 2.6.0.48, JGS524Ev2 versiones anteriores a 2.6.0.48, JGS524PE versiones anteriores a 2.6.0.48 y GS116Ev2 versiones anteriores a 2.6.0.48. Se encontró un servidor TFTP activo por defecto. Permite a los usuarios remotos autentificados actualizar el firmware del switch"
}
],
"lastModified": "2026-06-17T03:14:20.313",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "83FA56EB-35CD-4A58-8019-C4597AAC0104",
"versionEndExcluding": "2.6.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "19D0AC3E-87B5-435A-B203-E9759A4A5396",
"versionEndExcluding": "2.6.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CFF899BD-AA1E-4C47-BCFD-5E32F75F538A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "62D7F6C3-8104-4C7D-AE9D-8C96D40221A3",
"versionEndExcluding": "2.6.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D4A32288-19B5-4A8F-B883-FCC326B7032D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9CCEFE31-BAA8-4791-BB66-27D341EAE6C7",
"versionEndExcluding": "2.6.0.48"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}