CVE-2020-28211
Estado: ModificadaAlta (7.8)—
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.33%
- Percentil entre todas las CVEs puntuadas: 24
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-863
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-28211",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)",
"versions": [
{
"status": "affected",
"version": "PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)"
}
]
}
]
}
],
"published": "2020-11-19T22:15:13.410",
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger."
},
{
"lang": "es",
"value": "CWE-863: Se presenta una vulnerabilidad Autorización Incorrecta en Simulador de PLC en EcoStruxureª Control Expert (ahora Unity Pro) (todas las versiones) que podría causar una omisión de la autenticación cuando se sobrescribe la memoria usando un depurador"
}
],
"lastModified": "2026-06-17T03:10:12.607",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "18E8CCC1-A467-4FEF-964D-8481EAE892EC"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}