CVE-2020-26198
Status: ModifiedMedium (6.1)—
Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Base score: 6.1
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 1.00%
- Percentile among all scored CVEs: 62
- Score date: 10/4/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-79
- CWE-79
References
Raw JSON (NVD)
Show
{
"id": "CVE-2020-26198",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "security_alert@emc.com",
"affectedData": [
{
"vendor": "Dell",
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "4.32.10.00 and 4.40.00.00",
"versionType": "custom"
}
]
}
]
}
],
"published": "2020-12-16T16:15:13.883",
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability",
"tags": [
"Vendor Advisory"
],
"source": "security_alert@emc.com"
},
{
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "security_alert@emc.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.32.10.00 y 4.40.00.00, contienen una vulnerabilidad de tipo cross-site scripting reflejada en la aplicación web de iDRAC9. Un atacante remoto podría potencialmente explotar esta vulnerabilidad para ejecutar HTML o JavaScript maliciosos en el navegador de una víctima engañándola para que siga un enlace especialmente diseñado"
}
],
"lastModified": "2026-06-17T03:07:48.847",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61EDDB16-D51C-440B-AEB5-3F087BC5E5A0",
"versionEndIncluding": "4.32.10.00"
},
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:4.40.00.00:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F478B785-B01A-4715-A2E0-ED239299BDE0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "security_alert@emc.com"
}