CVE-2020-16218
Estado: ModificadaBaja (3.5)—
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 3.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.65%
- Percentil entre todas las CVEs puntuadas: 50
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-16218",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.7,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:N/A:N",
"authentication": "SINGLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.1,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Philips",
"product": "Patient Information Center iX (PICiX)",
"versions": [
{
"status": "affected",
"version": "B.02"
},
{
"status": "affected",
"version": "C.02"
},
{
"status": "affected",
"version": "C.03"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2020-09-11T13:15:11.237",
"references": [
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.philips.com/productsecurity",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.philips.com/productsecurity",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the \nsoftware does not neutralize or incorrectly neutralizes \nuser-controllable input before it is placed in output that is then used \nas a webpage and served to other users. Successful exploitation could \nlead to unauthorized access to patient data via a read-only web \napplication."
},
{
"lang": "es",
"value": "Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, Monitores de paciente IntelliVue MX100, MX400-MX850 y MP2-MP90 Versiones N y anteriores, IntelliVue X3 y X2 Versiones N y anteriores. El software no neutraliza o neutraliza incorrectamente la entrada controlable por el usuario antes de colocarla en la salida que luego es usado como una página web y es servido a otros usuarios. La explotación con éxito podría conllevar a un acceso no autorizado a los datos del paciente por medio de una aplicación web de solo lectura"
}
],
"lastModified": "2026-06-17T02:57:52.740",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4FA1FEC-5139-48C1-856C-8062436AE6C6"
},
{
"criteria": "cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F3220AB2-AC0D-4AC2-90D8-76C02FC693EB"
},
{
"criteria": "cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AE1FB3E9-E269-434A-B1C2-D54C40F437BE"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}