CVE-2020-14494
Estado: ModificadaCrítica (9.8)—
OpenClinic GA versions 5.09.02 and 5.89.05b contain an authentication mechanism within the system that does not provide sufficient complexity to protect against brute force attacks, which may allow unauthorized users to access the system after no more than a fixed maximum number of attempts.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.31%
- Percentil entre todas las CVEs puntuadas: 70
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
- CWE-307
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-14494",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "n/a",
"product": "OpenClinic GA",
"versions": [
{
"status": "affected",
"version": "Versions 5.09.02 and 5.89.05b"
}
]
}
]
}
],
"published": "2020-07-20T15:15:12.930",
"references": [
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-307"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "OpenClinic GA versions 5.09.02 and 5.89.05b contain an authentication mechanism within the system that does not provide sufficient complexity to protect against brute force attacks, which may allow unauthorized users to access the system after no more than a fixed maximum number of attempts."
},
{
"lang": "es",
"value": "OpenClinic GA versiones 5.09.02 y 5.89.05b, contienen un mecanismo de autenticación dentro del sistema que no proporciona suficiente complejidad para proteger contra ataques de fuerza bruta, lo que puede permitir a usuarios no autorizados acceder al sistema después de no más de un número máximo fijado de intentos"
}
],
"lastModified": "2026-06-17T02:54:51.967",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.09.02:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A64E5CCD-1F0D-46B2-9AE7-C917928D2788"
},
{
"criteria": "cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.89.05b:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BE2E5CDB-B864-45E4-A7EA-D7EE93BC2453"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}