CVE-2020-12007
Estado: ModificadaCrítica (9.8)—
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.94%
- Percentil entre todas las CVEs puntuadas: 90
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (11)
CWE
- CWE-502
- CWE-502
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-12007",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Mitsubishi Electric",
"product": "MC Works64",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"vendor": "Mitsubishi Electric",
"product": "MC Works32",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"vendor": "ICONICS",
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"vendor": "ICONICS",
"product": "GenBroker32",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
]
}
],
"published": "2020-07-16T22:15:11.337",
"references": [
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C",
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
},
{
"lang": "es",
"value": "Un paquete de comunicación especialmente diseñado enviado a los dispositivos afectados podría permitir una ejecución de código remota y una condición de denegación de servicio debido a una vulnerabilidad de deserialización. Este problema afecta: Mitsubishi Electric MC Works64 versión 4.02C (10.95.208.31) y anteriores, todas las versiones; Mitsubishi Electric MC Works32 versión 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server versión 10.96 y anteriores; ICONICS GenBroker32 versión 9.5 y anteriores"
}
],
"lastModified": "2026-06-17T02:51:14.557",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mitsubishielectric:mc_works:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C9B1F646-0D54-4B3A-B39A-A45E1A0615EB",
"versionEndIncluding": "10.95.208.31"
},
{
"criteria": "cpe:2.3:a:mitsubishielectric:mc_works32:9.50.255.02:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A68D91E4-0C65-45F0-965E-A6AAE0E2F09F"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:iconics:energy_analytix:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DD143148-B191-4D8E-9C28-09D4AC5D192C"
},
{
"criteria": "cpe:2.3:a:iconics:facility_analytix:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BE3C5226-94D4-4826-9B76-72626081DF46"
},
{
"criteria": "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "17E644D8-AB8E-4E3C-AE4B-64D3BBCC30BF"
},
{
"criteria": "cpe:2.3:a:iconics:hyper_historian:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "78FF2A71-4918-491E-A5D8-DEB9E17FA6E4"
},
{
"criteria": "cpe:2.3:a:iconics:mobilehmi:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16745C56-A59A-4C38-92E1-FC5C63220989"
},
{
"criteria": "cpe:2.3:a:iconics:quality_analytix:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "717A4B7B-2A42-4A9C-961F-1EA5E62FB188"
},
{
"criteria": "cpe:2.3:a:iconics:smart_energy_analytix:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5082C435-FCCD-4CF6-891E-73F846A6FB40"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:iconics:bizviz:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CF628CB2-BCA9-4E69-A9CB-846577F98DA1"
},
{
"criteria": "cpe:2.3:a:iconics:genesis32:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "771DB32A-CD85-4638-B90E-25D9B4951DE5"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}