« Back to list

CVE-2020-10611

Status: ModifiedCritical (9.8)—

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2020-10611",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122",
          "versions": [
            {
              "status": "affected",
              "version": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-04-15T19:15:13.613",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-843"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-843"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."
    },
    {
      "lang": "es",
      "value": "Triangle MicroWorks SCADA Data Gateway versiones 3.02.0697 hasta 4.0.122, versiones 2.41.0213 hasta 4.0.122, permite a atacantes remotos ejecutar código arbitrario debido a la falta de comprobación apropiada de los datos suministrados por el usuario, lo que puede causar una condición de confusión de tipos. No es requerida una autenticación para explotar esta vulnerabilidad. Solo aplicable a instalaciones que utilizan DNP3 Data Sets."
    }
  ],
  "lastModified": "2026-06-17T02:48:05.810",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3F22582F-32D4-4E3A-AF76-CDB180CC0D03",
              "versionEndIncluding": "4.0.122",
              "versionStartIncluding": "2.41.0213"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}