CVE-2020-10066
Status: ModifiedMedium (5.7)—
Incorrect Error Handling in Bluetooth HCI core. Zephyr versions >= v1.14.2, >= v2.2.0 contain NULL Pointer Dereference (CWE-476). For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-gc66-xfrc-24qr
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
- Base score: 5.7
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.21%
- Percentile among all scored CVEs: 10
- Score date: 10/7/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-476
- CWE-476
References
Raw JSON (NVD)
Show
{
"id": "CVE-2020-10066",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vulnerabilities@zephyrproject.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.5,
"attackVector": "LOCAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.7,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "vulnerabilities@zephyrproject.org",
"affectedData": [
{
"vendor": "zephyrproject-rtos",
"product": "zephyr",
"versions": [
{
"status": "affected",
"version": "v1.14.2",
"lessThan": "unspecified",
"versionType": "custom"
},
{
"status": "affected",
"version": "v2.2.0",
"lessThan": "unspecified",
"versionType": "custom"
}
]
}
]
}
],
"published": "2021-05-25T17:15:07.617",
"references": [
{
"url": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-gc66-xfrc-24qr",
"tags": [
"Patch",
"Third Party Advisory"
],
"source": "vulnerabilities@zephyrproject.org"
},
{
"url": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-gc66-xfrc-24qr",
"tags": [
"Patch",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnerabilities@zephyrproject.org",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Error Handling in Bluetooth HCI core. Zephyr versions >= v1.14.2, >= v2.2.0 contain NULL Pointer Dereference (CWE-476). For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-gc66-xfrc-24qr"
},
{
"lang": "es",
"value": "Un Manejo Incorrecto de Errores en el core HCI de Bluetooth. Zephyr versiones posteriores a v1.14.2 incluyéndola, versiones posteriores a v2.2.0 incluyéndola contienen una desreferencia de puntero NULL (CWE-476). Para mayor información, consulte https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-gc66-xfrc-24qr"
}
],
"lastModified": "2026-06-17T02:47:17.337",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "04446C3A-F3CE-4015-99BB-40441B2FB274",
"versionEndIncluding": "1.14.2"
},
{
"criteria": "cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "28C09876-67B1-49DF-835A-5AC7201CBE3D",
"versionEndIncluding": "2.2.0",
"versionStartIncluding": "2.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vulnerabilities@zephyrproject.org"
}