« Volver al listado

CVE-2019-9134

Estado: ModificadaCrítica (9.8)—

Architectural Information System 1.0 and earlier versions have a Stack-based buffer overflow, allows remote attackers to execute arbitrary code.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-9134",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "vuln@krcert.or.kr",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.4,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.4
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "vuln@krcert.or.kr",
      "affectedData": [
        {
          "vendor": "Solideo Systems Co,Ltd",
          "product": "Architectural Information System",
          "versions": [
            {
              "status": "affected",
              "version": "Architectual Information system",
              "versionType": "custom",
              "lessThanOrEqual": "1.0"
            }
          ],
          "platforms": [
            "x86, x84"
          ]
        }
      ]
    }
  ],
  "published": "2019-04-09T18:29:01.063",
  "references": [
    {
      "url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=34993",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "vuln@krcert.or.kr"
    },
    {
      "url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=34993",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "vuln@krcert.or.kr",
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Architectural Information System 1.0 and earlier versions have a Stack-based buffer overflow, allows remote attackers to execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "Architectural Information System versión 1.0 y versiones anteriores, tienen un desbordamiento de búfer en la región stack de la memoria, lo que permite a los atacantes remotos ejecutar código arbitrario."
    }
  ],
  "lastModified": "2026-06-17T02:43:07.597",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:solideos:architectural_information_system:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3E04894D-C2AB-42D2-9F78-A3584278EE51",
              "versionEndIncluding": "1.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "vuln@krcert.or.kr"
}