CVE-2019-8268
Estado: ModificadaCrítica (9.8)—
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.92%
- Percentil entre todas las CVEs puntuadas: 90
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-193
- CWE-193
Referencias
- https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf
- https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/
- https://www.us-cert.gov/ics/advisories/icsa-20-161-06
- https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf
- https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/
- https://www.us-cert.gov/ics/advisories/icsa-20-161-06
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-8268",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vulnerability@kaspersky.com",
"affectedData": [
{
"vendor": "Kaspersky Lab",
"product": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
]
}
],
"published": "2019-03-08T23:29:00.623",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"tags": [
"Third Party Advisory"
],
"source": "vulnerability@kaspersky.com"
},
{
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/",
"tags": [
"Third Party Advisory"
],
"source": "vulnerability@kaspersky.com"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "vulnerability@kaspersky.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnerability@kaspersky.com",
"description": [
{
"lang": "en",
"value": "CWE-193"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-193"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."
},
{
"lang": "es",
"value": "UltraVNC, en su revisión 1206, tiene múltiples vulnerabilidades de error por un paso en el código del cliente VNC conectadas con el uso incorrecto de la función ClientConnection::ReadString, lo cual puede resultar, potencialmente, en la ejecución de código. Este ataque parece ser explotable mediante la conectividad de red. Se han solucionado estas vulnerabilidades en la revisión 1207."
}
],
"lastModified": "2026-06-17T02:41:46.940",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "555D034F-3D64-4ED1-9B63-F8D59199E99C",
"versionEndExcluding": "1.2.2.3"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinumerik_access_mymachine\\/p2p:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D9345335-DF62-4472-93CD-E2C85453F91E",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\/ipc:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7498412D-79FD-43FE-AD9B-5820FB5CF7D8",
"versionEndExcluding": "14.00"
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\/ipc:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F603341-03C5-46CA-8A74-EC5A50135194",
"versionEndIncluding": "12.01"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vulnerability@kaspersky.com"
}