CVE-2019-6824
Estado: ModificadaCrítica (9.8)—
A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.46%
- Percentil entre todas las CVEs puntuadas: 91
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-6824",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "ProClima",
"product": "ProClima all versions prior to version 8.0.0",
"versions": [
{
"status": "affected",
"version": "ProClima all versions prior to version 8.0.0"
}
]
}
]
}
],
"published": "2019-07-15T21:15:10.727",
"references": [
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0."
},
{
"lang": "es",
"value": "Una CWE-119: Se presenta una vulnerabilidad de Errores de búfer en ProClima (todas las versiones anteriores a la versión 8.0.0), que permite a un atacante remoto no autenticado ejecutar código arbitrario en el sistema de destino en todas las versiones de ProClima anteriores a la versión 8.0.0."
}
],
"lastModified": "2026-06-17T02:39:44.750",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1C7BB1CA-CCED-4EC9-81F4-16633561E4CF",
"versionEndExcluding": "8.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}