CVE-2019-6568
Estado: ModificadaAlta (7.5)—
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.40%
- Percentil entre todas las CVEs puntuadas: 72
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (53)
Siemens — Cp1604 FirmwareSiemens — Cp1616 FirmwareSiemens — Simatic Cp343-1 Advanced FirmwareSiemens — Simatic Cp443-1 Advanced FirmwareSiemens — Simatic Cp443-1 FirmwareSiemens — Simatic Cp443-1 OPC UASiemens — Simatic ET 200 SP Open Controller CPU 1515sp PC2 FirmwareSiemens — Simatic ET 200 SP Open Controller CPU 1515sp PC FirmwareSiemens — Simatic HMI Comfort Outdoor Panels FirmwareSiemens — Simatic HMI Comfort Panels FirmwareSiemens — Simatic HMI KTP Mobile Panels Ktp400f FirmwareSiemens — Simatic HMI KTP Mobile Panels Ktp700 FirmwareSiemens — Simatic HMI KTP Mobile Panels Ktp700f FirmwareSiemens — Simatic HMI KTP Mobile Panels Ktp900 FirmwareSiemens — Simatic HMI KTP Mobile Panels Ktp900f FirmwareSiemens — Simatic IPC DiagmonitorSiemens — Simatic Rf181-eip FirmwareSiemens — Simatic Rf182c FirmwareSiemens — Simatic Rf185c FirmwareSiemens — Simatic Rf186c FirmwareSiemens — Simatic Rf188c FirmwareSiemens — Simatic Rf600r FirmwareSiemens — Simatic S7-1500 FirmwareSiemens — Simatic S7-1500 Software ControllerSiemens — Simatic S7-1500f FirmwareSiemens — Simatic S7-1500s FirmwareSiemens — Simatic S7-1500t FirmwareSiemens — Simatic S7-300 FirmwareSiemens — Simatic S7-400 Pn/dp FirmwareSiemens — Simatic S7-400 PN FirmwareSiemens — Simatic S7-plcsim AdvancedSiemens — Simatic Teleservice Adapter IE Advanced FirmwareSiemens — Simatic Teleservice Adapter IE Basic FirmwareSiemens — Simatic Teleservice Adapter IE Standard FirmwareSiemens — Simatic Winac RTX FirmwareSiemens — Simatic Wincc Runtime AdvancedSiemens — Simocode PRO V EIP FirmwareSiemens — Simocode PRO V PN FirmwareSiemens — Sinamics G130 FirmwareSiemens — Sinamics G150 FirmwareSiemens — Sinamics Gh150 FirmwareSiemens — Sinamics Gl150 FirmwareSiemens — Sinamics Gm150 FirmwareSiemens — Sinamics S120 FirmwareSiemens — Sinamics S150 FirmwareSiemens — Sinamics S210 FirmwareSiemens — Sinamics Sl150 FirmwareSiemens — Sinamics Sm120 FirmwareSiemens — Sinamics Sm150 FirmwareSiemens — Sitop ManagerSiemens — Sitop Psu8600 FirmwareSiemens — Sitop Ups1600 FirmwareSiemens — TIM 1531 IRC Firmware
CWE
- CWE-125
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-6568",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-6568",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-03T13:27:45.600260Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIMATIC CP 1604",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 1616",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 343-1 Advanced",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 443-1",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 443-1",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 443-1 Advanced",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC CP 443-1 OPC UA",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.1.6"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.7"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Upd4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Upd4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Upd4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC DiagMonitor",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RF182C",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RF185C",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RF186C",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RF188C",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RF600R family",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.1"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC RFID 181EIP",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.6.1"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 Software Controller",
"versions": [
{
"status": "affected",
"version": "All versions < V2.7"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-PLCSIM Advanced",
"versions": [
{
"status": "affected",
"version": "All versions < V2.0 SP1 UPD1"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Teleservice Adapter IE Basic",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC Teleservice Adapter IE Standard",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC WinAC RTX 2010",
"versions": [
{
"status": "affected",
"version": "All versions < V2010 SP3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC WinAC RTX F 2010",
"versions": [
{
"status": "affected",
"version": "All versions < V2010 SP3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC WinCC Runtime Advanced",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Upd4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.1.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V4.6 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V4.7 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V4.7 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V4.8 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 HF6"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V5.1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G130 V5.1 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1 SP1 HF4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V4.6 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V4.7 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V4.7 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V4.8 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 HF6"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V5.1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS G150 V5.1 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1 SP1 HF4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GH150 V4.7 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GH150 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 SP2 HF9"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GL150 V4.7 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GL150 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 SP2 HF9"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GM150 V4.7 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS GM150 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 SP2 HF9"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 HF6"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1 SP1 HF4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V4.6 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V4.7 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V4.7 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V4.8 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 HF6"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V5.1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S150 V5.1 SP1 Control Unit",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1 SP1 HF4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS S210",
"versions": [
{
"status": "affected",
"version": "All versions < V5.1 SP1 HF8"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS SL150 V4.7 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.7 HF33"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS SL150 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS SM120 V4.7 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS SM120 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8 SP2 HF10"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SINAMICS SM150 V4.8 (Control Unit)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS NET CP 343-1 Advanced",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS NET CP 443-1",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS NET CP 443-1 Advanced",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.3.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"versions": [
{
"status": "affected",
"version": "All versions < V3.2.16"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SITOP Manager",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SITOP PSU8600",
"versions": [
{
"status": "affected",
"version": "All versions < V1.5"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SITOP UPS1600 (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.3"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V2.1"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2019-04-17T14:29:03.683",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
},
{
"lang": "es",
"value": "SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" - 22\" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles móviles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 y variantes SIPLUS), controlador de software SIMATIC S7-1500, familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incluidas las variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incluidas las variantes SIPLUS) SIPLUS), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS), SIMOCODE pro V PN (incl. variantes SIPLUS), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5. 1 SP1 Unidad de control, SINAMICS G150 V4.6 Unidad de control, SINAMICS G150 V4.7 Unidad de control, SINAMICS G150 V4.7 SP1 Unidad de control, SINAMICS G150 V4.8 Unidad de control, SINAMICS G150 V5. 1 Unidad de control, SINAMICS G150 V5.1 SP1 Unidad de control, SINAMICS GH150 V4.7 (Unidad de control), SINAMICS GH150 V4.8 (Unidad de control), SINAMICS GL150 V4.7 (Unidad de control), SINAMICS GL150 V4. 8 (Unidad de control), SINAMICS GM150 V4.7 (Unidad de control), SINAMICS GM150 V4.8 (Unidad de control), SINAMICS S120 V4.6 Unidad de control (incl. variantes SIPLUS), SINAMICS S120 V4.7 Unidad de control (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V4.7 SP1 (incl. variantes SIPLUS), SINAMICS S120 V4.8 (incl. variantes SIPLUS), SINAMICS S120 V5.1 (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V5.1 SP1 Unidad de Control (incl. variantes SIPLUS), SINAMICS S150 V4.6 Unidad de Control, SINAMICS S150 V4.7 Unidad de Control, SINAMICS S150 V4.7 SP1 Unidad de Control, SINAMICS S150 V4. 8 Unidad de control, SINAMICS S150 V5.1 Unidad de control, SINAMICS S150 V5.1 SP1 Unidad de control, SINAMICS S210 V5.1 Unidad de control, SINAMICS S210 V5.1 SP1 Unidad de control, SINAMICS SL150 V4. 7 (Unidad de Control), SINAMICS SL150 V4.8 (Unidad de Control), SINAMICS SM120 V4.7 (Unidad de Control), SINAMICS SM120 V4.8 (Unidad de Control), SINAMICS SM150 V4. 8 (unidad de control), SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. variantes SIPLUS), TIM 1531 IRC (incl. variantes SIPLUS NET). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conducir a una condición de denegación de servicio. Un atacante puede provocar una situación de denegación de servicio que lleve a reiniciar el servidor web del dispositivo afectado. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo"
}
],
"lastModified": "2026-06-17T02:39:16.410",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E737620D-9D00-4151-B232-7DFB7FD768B3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6222006F-09D7-49F7-B8C7-4D94298A8F6A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "65FE6F54-1457-4EB6-9273-1D93B3B97386"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "184365A2-BAD2-4926-ACEE-F71E018D3CE5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "69EE2BF6-3846-478F-9AC6-BEF34617F3B5",
"versionEndExcluding": "1.1.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E6601B8-E032-4B39-BF65-F25CF047EB99"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp343-1_advanced:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "ACCC0229-E454-4BEF-931A-3CD820500822"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2035A020-F41E-4FC7-A290-9923574D4921"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp443-1:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EB8636E9-A3DA-4DDC-A3FC-B3EAAD07952E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1AD15638-8B84-4DA2-9DDC-9A1CA3548E91"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp443-1_advanced:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BFE94F56-71DB-4837-9818-6827C80DE2BC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D1873751-81F4-4732-B30F-9F2DEECBC110",
"versionEndExcluding": "2.1.6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F36AC571-C958-4CB8-91D9-5417C1812C02",
"versionEndExcluding": "2.7"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "00361A3C-60E9-4365-BB51-09D7792C441D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "865FD012-F390-4BB8-B14F-533840B95512",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5418D916-49A6-4B79-A653-E2C5221DEBE8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "56396833-12BF-4AE5-8D3E-695652A99DBF"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6FD49A39-47D7-473C-9E46-6D9246BC6D04",
"versionEndExcluding": "5.1.3"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "11C0A94D-5506-4A75-99E1-CA9769AF057C",
"versionEndExcluding": "2.7"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8B66A2A4-5062-45F8-A615-2DA716650909",
"versionEndExcluding": "2.0"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AED3A3AF-EF77-4E58-91AD-BBE01E1DA4A6"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "23039930-E45C-4B0E-883A-E2F9A7502984"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015"
},
{
"criteria": "cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2662688E-6975-46C7-939B-25FF4790518D",
"versionEndExcluding": "1.1"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16CBED3D-892A-4EC0-BE2E-358040C34304",
"versionEndExcluding": "3.2.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "25F96DAA-696D-4EB4-97DF-986C7681700B",
"versionEndExcluding": "1.1.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CF8FFD1C-8E33-48E9-A884-B80311F8BA4C",
"versionEndExcluding": "1.1.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AFA94867-4367-4186-8A4B-44C3CBCCEF7F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_rf181-eip:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E10A0D57-8805-44DB-95E3-1B240ED5ED09"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2AE766CD-695B-4A12-8BC5-3743D8E3D73E",
"versionEndExcluding": "2.6.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0A2219FE-2C3F-4948-85D6-3C53AC08722B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "795D0FF9-1D0B-4C74-BEF3-58EAE74DFA0C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BC917346-94F6-44FD-AC00-AED0CF3CBBD1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F60D816D-85A5-4971-AF2D-666AE0B74E9E"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "71DA3D1A-E435-418F-9A13-945B4BA15FC7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
"versionEndExcluding": "2010"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simocode_pro_v_eip_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8A001968-C7FD-4C11-8439-11532B234CC2",
"versionEndExcluding": "1.1.3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simocode_pro_v_eip:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "50BDA360-0D33-42DC-ADB9-2F69503C2CD8"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simocode_pro_v_pn_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "15CB26DA-7CA0-4BD6-A219-01F6E8A6F03F",
"versionEndExcluding": "2.1.3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simocode_pro_v_pn:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1779AE78-AC90-48BE-8FF2-CC11E7CA3CB4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79",
"versionEndExcluding": "5.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096",
"versionEndExcluding": "5.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0",
"versionEndExcluding": "5.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "126AC93E-A39F-4754-9707-207C9F2F64F4",
"versionEndExcluding": "5.1"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3E8BCCED-BDC6-4785-8705-799836E5024E"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "098262CC-4D3B-4E55-83C3-2816403C553B"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1_hotfix2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6092F899-9A89-4FA4-BD80-97511DF7CF8F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B7269713-6505-41DF-B85B-F729E24A3F5B",
"versionEndExcluding": "5.1"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BEBF14B3-65A0-41E9-B99C-D88548F307CD"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F151297C-3097-483F-98B5-0261BD547421"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6F389808-001E-4650-86B2-00A72D25BCD0",
"versionEndExcluding": "1.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sitop_ups1600_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BD39CC96-ABE3-4854-A102-36AFE1F6CB14",
"versionEndExcluding": "2.3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sitop_ups1600:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6FC1A64E-6A27-4F91-8A13-829E0F7D8E80"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B023E75A-B76D-4FD8-9660-1F233092160F",
"versionEndExcluding": "2.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F9C47A4A-BE81-499A-AB36-491661B88693",
"versionEndExcluding": "2.6.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "66A446D2-39ED-4635-AAA0-85D977F600FE",
"versionEndExcluding": "2.6.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5238622A-BCAD-4A06-9920-49BECFDDC2A6",
"versionEndExcluding": "2.6.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6D076504-AFE3-4C51-80E5-C5992CA7D511"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B",
"versionEndExcluding": "4.8"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FC70D596-AA1E-4196-87B0-BECEE6568AA7",
"versionEndExcluding": "5.1"
},
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:5.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E81CDB5-122F-48D1-B9F1-4C401D46D978"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}