CVE-2019-6567

Medium (5.5)—
Routine follow-upSeverity Medium 5.5. No public exploit or active exploitation known.
Severity5.5Medium · CVSS 3.1
Exploitation probability0.30 %higher than 15% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 04:00 PM
Public exploitNot knownno public code found

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (4)

NVD record

NVD status
Modified
Published
Jun 12, 2019
Last modified
Jun 17, 2026
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Weakness (CWE)
CWE-257, CWE-522

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2019-6567",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 2.1,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions < V5.2.4"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V5.5.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V4.1.3"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE X-414-3E",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-06-12T14:29:04.820",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-257"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.2.4), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.5.0), familia de switches SCALANCE X-300 (incluyendo X408 y las variantes SIPLUS NET) (Todas las versiones anteriores a V4.1.3), SCALANCE X-414-3E (Todas las versiones). Los dispositivos afectados almacenan contraseñas en un formato recuperable. Un atacante puede extraer y recuperar contraseñas de dispositivos desde la configuración del dispositivo. La explotación exitosa requiere acceso a una copia de seguridad de la configuración del dispositivo e impacta la confidencialidad de las contraseñas almacenadas. En el momento de la publicación del aviso no se conocía la explotación pública de esta vulnerabilidad de seguridad"
    }
  ],
  "lastModified": "2026-06-17T02:39:16.300",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "443B5E7B-A491-4883-9853-A88D3B24E220",
              "versionEndExcluding": "5.2.4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6FEF9F9F-4066-483B-BF95-3BA5625284DF"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "602CAF2E-2276-455C-82E5-A05BBFC198C5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3F2C50BB-CC63-40BE-A5F0-0F0C342586CA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x-414-3e_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C9B3E06E-8822-406C-907A-40AE328B311C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-414-3e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CE7762EE-1253-4A4B-81CF-1A6423135AB6"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}