CVE-2019-5641
Estado: ModificadaMedia (5.3)—
Rapid7 InsightVM suffers from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the Inspect Element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.38%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-200
- CWE-613
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-5641",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-5641",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-27T18:41:24.403832Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve@rapid7.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.3,
"attackVector": "LOCAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@rapid7.com",
"affectedData": [
{
"vendor": "Rapid7",
"product": "InsightVM",
"versions": [
{
"status": "affected",
"version": "6.6.160",
"versionType": "custom",
"lessThanOrEqual": "6.6.160"
}
]
}
]
}
],
"published": "2022-09-21T15:15:10.243",
"references": [
{
"url": "https://docs.rapid7.com/release-notes/insightvm/20220830/",
"tags": [
"Vendor Advisory"
],
"source": "cve@rapid7.com"
},
{
"url": "https://docs.rapid7.com/release-notes/insightvm/20220830/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cve@rapid7.com",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-613"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rapid7 InsightVM suffers from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the Inspect Element browser feature to remove the login panel and view the details available in the last webpage visited by previous user"
},
{
"lang": "es",
"value": "Rapid7 InsightVM sufre un problema de exposición de información por el que, cuando la sesión del usuario ha finalizado por inactividad, un atacante puede usar la función del navegador Inspect Element para eliminar el panel de acceso y visualizar los detalles disponibles en la última página web visitada por el usuario anterior"
}
],
"lastModified": "2026-06-17T02:38:00.850",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rapid7:insightvm:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "92D55F81-2863-4161-A9BE-D9845CEA085F",
"versionEndIncluding": "6.6.160"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@rapid7.com"
}