CVE-2019-5175
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1ea28 the extracted type value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=<contents of type node> using sprintf(). This command is later executed via a call to system().
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.36%
- Percentil entre todas las CVEs puntuadas: 71
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-5175",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.2,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "Wago",
"product": "WAGO PFC200",
"versions": [
{
"status": "affected",
"version": "Firmware version 03.02.02(14)"
}
]
}
]
}
],
"published": "2020-03-11T23:15:11.747",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0962",
"tags": [
"Exploit",
"Mitigation",
"Technical Description",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0962",
"tags": [
"Exploit",
"Mitigation",
"Technical Description",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1ea28 the extracted type value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=<contents of type node> using sprintf(). This command is later executed via a call to system()."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de inyección de comando explotable en la función \"I/O-Check\" del servicio iocheckd de WAGO PFC 200 en la versión de firmware 03.02.02(14). Un archivo cache XML especialmente diseñado escrito en una ubicación específica en el dispositivo puede ser usado para inyectar comandos de Sistema Operativo. Un atacante puede enviar un paquete especialmente diseñado para activar el análisis de este archivo cache. En 0x1ea28, el valor de tipo extraído del archivo xml es usado como argumento para /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=(contents of type node) usando la función sprintf(). Este comando luego es ejecutado por medio de una llamada a la función system()."
}
],
"lastModified": "2026-06-17T02:37:15.753",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:wago:pfc200_firmware:03.02.02\\(14\\):*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6274B67D-C65B-4834-9DB5-6FB3D0ADD3A9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "688A3248-7EAA-499D-A47C-A4D4900CDBD1"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}