« Volver al listado

CVE-2019-3985

Estado: ModificadaAlta (8.8)—

Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due to improperly sanitized input when configuring the devices wifi configuration via the ssid parameter.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-3985",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 8.3,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "vulnreport@tenable.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Amazon's Blink XT2 Sync Module",
          "versions": [
            {
              "status": "affected",
              "version": "All firmware versions prior to version 2.13.11"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-12-11T23:15:11.227",
  "references": [
    {
      "url": "https://www.tenable.com/security/research/tra-2019-51",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "vulnreport@tenable.com"
    },
    {
      "url": "https://www.tenable.com/security/research/tra-2019-51",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due to improperly sanitized input when configuring the devices wifi configuration via the ssid parameter."
    },
    {
      "lang": "es",
      "value": "El firmware de Blink XT2 Sync Module versiones anteriores a 2.13.11, permite a atacantes remotos ejecutar comandos arbitrarios en el dispositivo debido a una entrada saneada inapropiadamente cuando se establece la configuración wifi del dispositivo por medio del parámetro ssid."
    }
  ],
  "lastModified": "2026-06-17T02:35:59.930",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:amazon:blink_xt2_sync_module_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FFEE7C5F-CA30-4B2D-A0EE-B7425144489E",
              "versionEndExcluding": "2.13.11"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:amazon:blink_xt2_sync_module:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5AFBC607-8887-4CC7-99D0-60D9C8993EE9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com"
}