CVE-2019-25720
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.20%
- Percentil entre todas las CVEs puntuadas: 9
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement60 % - Impacto principal
T1499Endpoint Denial of Serviceimpact55 %
Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (5)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-1286
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-25720",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-25720",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-03T17:44:08.218138Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "Dräger",
"product": "SC 6002XL",
"versions": [
{
"status": "affected",
"version": "SC 6002XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC6802XL",
"versions": [
{
"status": "affected",
"version": "SC6802XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC 7000",
"versions": [
{
"status": "affected",
"version": "SC 7000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC8000",
"versions": [
{
"status": "affected",
"version": "SC8000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC90000 XL",
"versions": [
{
"status": "affected",
"version": "SC90000 XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-06-03T18:16:15.910",
"references": [
{
"url": "https://static.draeger.com/security/download/2019-11-27-Draeger-SC7000-SC9000-security-advisory-update-v1-5.pdf",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.vulncheck.com/advisories/dr-ger-sc-monitoring-devices-dos-via-malformed-network-packet",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-1286"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity."
},
{
"lang": "es",
"value": "Los dispositivos de monitorización Dräger SC (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contienen una vulnerabilidad de denegación de servicio en todas las versiones de software que permite a atacantes no autenticados reiniciar el monitor enviando un paquete de red malformado. Los atacantes pueden enviar repetidamente dichos paquetes malformados para interrumpir la monitorización del paciente hasta que el dispositivo vuelve a la configuración predeterminada y pierde la conectividad de red."
}
],
"lastModified": "2026-07-22T19:10:00.120",
"sourceIdentifier": "disclosure@vulncheck.com"
}