« Back to list

CVE-2019-20697

Status: ModifiedHigh (8.8)—

Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects GS728TPPv2 before 6.0.0.48, GS728TPv2 before 6.0.0.48, GS750E before 1.0.1.4, GS752TPP before 6.0.0.48, and GS752TPv2 before 6.0.0.48.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (5)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2019-20697",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.8,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "cve@mitre.org",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 5.3,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-04-16T19:15:23.760",
  "references": [
    {
      "url": "https://kb.netgear.com/000061232/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Switches-PSV-2019-0066",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://kb.netgear.com/000061232/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Switches-PSV-2019-0066",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects GS728TPPv2 before 6.0.0.48, GS728TPv2 before 6.0.0.48, GS750E before 1.0.1.4, GS752TPP before 6.0.0.48, and GS752TPv2 before 6.0.0.48."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR están afectados por un desbordamiento del búfer en la región stack de la memoria por parte de un atacante no autenticado. Esto afecta a GS728TPPv2 versiones anteriores a 6.0.0.48, GS728TPv2 versiones anteriores a 6.0.0.48, GS750E versiones anteriores a 1.0.1.4, GS752TPP versiones anteriores a 6.0.0.48, y GS752TPv2 versiones anteriores a 6.0.0.48."
    }
  ],
  "lastModified": "2026-06-17T02:30:58.830",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:gs728tpp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7C2653FD-09E5-4538-981C-B0DB9D8F0CE8",
              "versionEndExcluding": "6.0.0.48"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:gs728tpp:v2:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "FC4DE9FB-CAD5-45F9-A11C-1C20EE2FF3A1"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:gs728tp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FE90F6B4-5E72-4EC9-97E3-59D265B0A228",
              "versionEndExcluding": "6.0.0.48"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:gs728tp:v2:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7126D4F8-2E3C-478B-9BD2-8055DFB48D8D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:gs750e_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "280C5BF4-B929-4853-B991-4E83A92C1E17",
              "versionEndExcluding": "1.0.1.4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:gs750e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A56285CF-1BD8-4BB5-AC9C-9EDDFCFC9E5C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:gs752tpp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8B097324-51FF-4ACB-A53B-B88B16AD4F61",
              "versionEndExcluding": "6.0.0.48"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:gs752tpp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "995D8E9F-7AE6-4A17-A728-7190FB2CE8BC"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:gs752tp_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "87CD1D35-E150-44B0-9565-353ACC1BA92B",
              "versionEndExcluding": "6.0.0.48"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:gs752tp:v2:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CDD4D404-9A22-408B-89CF-5107B809CB90"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}