« Volver al listado

CVE-2019-20462

Estado: AplazadaMedia (5.3)—

An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-20462",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2019-20462",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-08T16:54:52.492218Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-11-07T21:15:05.470",
  "references": [
    {
      "url": "https://seclists.org/fulldisclosure/2024/Jul/14",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.alecto.nl",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2024/Jul/14",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used."
    },
    {
      "lang": "es",
      "value": "Se descubrió un problema en los dispositivos Alecto IVM-100 2019-11-12. El dispositivo cuenta con una interfaz serie a nivel de placa. Al conectarse a esta interfaz serie y reiniciar el dispositivo, se divulga una gran cantidad de información. Esto incluye la contraseña de visualización y la contraseña del punto de acceso Wi-Fi que el dispositivo utilizaba."
    }
  ],
  "lastModified": "2026-06-17T02:30:30.280",
  "sourceIdentifier": "cve@mitre.org"
}