CVE-2019-1895
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.28%
- Percentil entre todas las CVEs puntuadas: 83
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-306
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-1895",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-1895",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-19T17:21:13.837538Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "psirt@cisco.com",
"affectedData": [
{
"vendor": "Cisco",
"product": "Cisco Enterprise NFV Infrastructure Software",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "3.12.1",
"versionType": "custom"
}
]
}
]
}
],
"published": "2019-08-07T21:15:11.283",
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass",
"tags": [
"Vendor Advisory"
],
"source": "psirt@cisco.com"
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la implementación de la consola de Virtual Network Computing (VNC) de Enterprise NFV Infrastructure Software (NFVIS) de Cisco, podría permitir a un atacante remoto no autenticado acceder a la sesión de consola VNC de un usuario administrativo en un dispositivo afectado. La vulnerabilidad es debido a un mecanismo de autenticación insuficiente utilizado para establecer una sesión VNC. Un atacante podría explotar esta vulnerabilidad mediante la intercepción de una petición de sesión VNC de administrador antes de iniciar sesión. Una explotación con éxito podría permitir al atacante visualizar la sesión de la consola del administrador o interactuar con ella, permitiendo el acceso del administrador al dispositivo afectado."
}
],
"lastModified": "2026-08-24T18:22:58.150",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:enterprise_nfv_infrastructure_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C12E5A08-AF62-44CF-894F-02463B584329",
"versionEndExcluding": "3.12.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@cisco.com"
}