« Volver al listado

CVE-2019-17066

Estado: ModificadaAlta (7.8)—

In Ivanti WorkSpace Control before 10.4.40.0, a user can elevate rights on the system by hijacking certain user registries. This is possible because pwrgrid.exe first checks the Current User registry hives (HKCU) when starting an application with elevated rights.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-17066",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.2,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": true,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-05-18T22:15:12.703",
  "references": [
    {
      "url": "https://forums.ivanti.com/s/article/A-locally-authenticated-user-with-low-privileges-can-acquire-admin-privileges-by-hijacking-certain-user-registry-entries",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://forums.ivanti.com/s/article/A-locally-authenticated-user-with-low-privileges-can-acquire-admin-privileges-by-hijacking-certain-user-registry-entries",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Ivanti WorkSpace Control before 10.4.40.0, a user can elevate rights on the system by hijacking certain user registries. This is possible because pwrgrid.exe first checks the Current User registry hives (HKCU) when starting an application with elevated rights."
    },
    {
      "lang": "es",
      "value": "En Ivanti WorkSpace Control versiones anteriores a 10.4.40.0, un usuario puede elevar los derechos en el sistema mediante el secuestro de determinados registros de usuarios. Esto es posible porque el archivo pwrgrid.exe primero comprueba las colmenas del registro Current User (HKCU) al iniciar una aplicación con derechos elevados."
    }
  ],
  "lastModified": "2026-06-17T02:23:15.200",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ivanti:workspace_control:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CD88ED96-E029-4241-A3CE-364122D016AD",
              "versionEndExcluding": "10.4.40.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}