« Volver al listado

CVE-2019-16639

Estado: AnalizadaCrítica (9.8)—

An issue was found on the Ruijie EG-2000 series gateway. There is a newcli.php API interface without access control, which can allow an attacker (who only has web interface access) to use TELNET commands and/or show admin passwords via the mode_url=exec&command= substring. This affects EG-2000SE EG_RGOS 11.9 B11P1.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-16639",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2019-16639",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-07-17T17:25:44.269390Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:ruijie:eg-2000se_eg_rgos:*:*:*:*:*:*:*:*"
          ],
          "vendor": "ruijie",
          "product": "eg-2000se_eg_rgos",
          "versions": [
            {
              "status": "affected",
              "version": "11.9b11p1"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-07-16T17:15:10.430",
  "references": [
    {
      "url": "https://0x.mk/?p=239",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://0x.mk/?p=239",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was found on the Ruijie EG-2000 series gateway. There is a newcli.php API interface without access control, which can allow an attacker (who only has web interface access) to use TELNET commands and/or show admin passwords via the mode_url=exec&command= substring. This affects EG-2000SE EG_RGOS 11.9 B11P1."
    },
    {
      "lang": "es",
      "value": "Se encontró un problema en la puerta de enlace de la serie Ruijie EG-2000. Existe una interfaz API newcli.php sin control de acceso, lo que puede permitir a un atacante (que solo tiene acceso a la interfaz web) usar comandos TELNET y/o mostrar contraseñas de administrador a través de la subcadena mode_url=exec&command=. Esto afecta a EG-2000SE EG_RGOS 11.9 B11P1."
    }
  ],
  "lastModified": "2026-06-17T02:22:28.153",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ruijie:eg-2000se_firmware:11.9_b11p1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "86ACA09C-0D60-4FA3-830C-16CB8A75A654"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ruijie:eg-2000se:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "35ED8F72-0FBB-4155-A7A4-24CF413BE576"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}