CVE-2019-1592

Estado: ModificadaAlta (7.8)—

A vulnerability in the background operations functionality of Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker to gain elevated privileges as root on an affected device. The vulnerability is due to insufficient validation of user-supplied files on an affected device. An attacker could exploit this vulnerability by logging in to the CLI of the affected device and creating a crafted file in a specific directory on the filesystem. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-1592",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2019-1592",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-20T16:55:20.629823Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.2,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "psirt@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@cisco.com",
      "affectedData": [
        {
          "vendor": "Cisco",
          "product": "Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode 11.0.1b",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified",
              "lessThan": "14.1(1i)",
              "versionType": "custom"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-05-03T15:29:00.650",
  "references": [
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-aci-hw-clock-util",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@cisco.com"
    },
    {
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-aci-hw-clock-util",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-264"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the background operations functionality of Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker to gain elevated privileges as root on an affected device. The vulnerability is due to insufficient validation of user-supplied files on an affected device. An attacker could exploit this vulnerability by logging in to the CLI of the affected device and creating a crafted file in a specific directory on the filesystem. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en la  funcionalidad background operations de Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) podría permitir a un atacante local identificado conseguir  privilegios elevados tipo root en un dispositivo afectado. La vulnerabilidad se debe a una comprobación insuficiente de los archivos provistos por el usuario en un dispositivo afectado. Un atacante podría operar esta vulnerabilidad si inicia sesión en la CLI del dispositivo afectado y crea un archivo diseñado en un directorio específico del sistema de archivos. Una función con éxito podría permitir al atacante ejecutar comandos de sistema operativo arbitrarios como tipo root en un dispositivo afectado."
    }
  ],
  "lastModified": "2026-06-17T02:28:48.667",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:nx-os:14.1\\(0.90\\):*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3CCA9D39-6270-4EEC-B3C0-D33877C503A4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8EBEBA5B-5589-417B-BF3B-976083E9FE54"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4283E433-7F8C-4410-B565-471415445811"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_92300yc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F80AB6FB-32FD-43D7-A9F1-80FA47696210"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D5B2E4C1-2627-4B9D-8E92-4B483F647651"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "11411BFD-3F4D-4309-AB35-A3629A360FB0"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E663DE91-C86D-48DC-B771-FA72A8DF7A7C"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A90184B3-C82F-4CE5-B2AD-97D5E4690871"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4AB89849-6DA4-4C9D-BC3F-EE0E41FD1901"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "07DE6F63-2C7D-415B-8C34-01EC05C062F3"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F423E45D-A6DD-4305-9C6A-EAB26293E53A"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93180lc-ex:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E952A96A-0F48-4357-B7DD-1127D8827650"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F70D81F1-8B12-4474-9060-B4934D8A3873"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7349D69B-D8FA-4462-AA28-69DD18A652D9"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "91231DC6-2773-4238-8C14-A346F213B5E5"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2DF88547-BAF4-47B0-9F60-80A30297FCEB"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "113772B6-E9D2-4094-9468-3F4E1A87D07D"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F1FC2B1F-232E-4754-8076-CC82F3648730"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9336pq:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5F1127D2-12C0-454F-91EF-5EE334070D06"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "17C7E3DB-8E1A-47AD-B1C5-61747DC0CFB9"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "63842B25-8C32-4988-BBBD-61E9CB09B4F3"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4364ADB9-8162-451D-806A-B98924E6B2CF"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9372px-e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B53BCB42-ED61-4FCF-8068-CB467631C63C"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "49E0371B-FDE2-473C-AA59-47E1269D050F"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9372tx-e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "489D11EC-5A18-4F32-BC7C-AC1FCEC27222"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1BC5293E-F2B4-46DC-85DA-167EA323FCFD"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EA022E77-6557-4A33-9A3A-D028E2DB669A"
            },
            {
              "criteria": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DDC2F709-AFBE-48EA-A3A2-DA1134534FB6"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "psirt@cisco.com"
}