CVE-2019-14927
Status: ModifiedHigh (7.5)—
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Base score: 7.5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 42%
- Percentile among all scored CVEs: 99
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (2)
CWEs
- CWE-306, CWE-425
References
Raw JSON (NVD)
Show
{
"id": "CVE-2019-14927",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-10-28T13:15:10.773",
"references": [
{
"url": "https://www.mogozobo.com/",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.mogozobo.com/?p=3593",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.mogozobo.com/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.mogozobo.com/?p=3593",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
},
{
"lang": "en",
"value": "CWE-425"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)."
},
{
"lang": "es",
"value": "Se descubrió un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versión 2.02 y los dispositivos INEA ME-RTU versiones hasta la versión 3.0. Una vulnerabilidad de descarga de configuración remota no autenticada permite a un atacante descargar el archivo de configuración de smartRTU (que contiene datos como nombres de usuario, contraseñas y otros datos confidenciales de RTU)."
}
],
"lastModified": "2026-06-17T02:19:20.027",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166",
"versionEndIncluding": "2.02"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1EF90DA0-55C7-4765-9DEE-80145752961D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DDC6C049-B15B-4FC2-9DDF-915381E6D114",
"versionEndIncluding": "3.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FD7F8299-4A9C-4B93-A35A-68C6D43855CC"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}