« Volver al listado

CVE-2019-13925

Estado: ModificadaAlta (7.5)—

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-13925",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SCALANCE S602",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V3.0 and < V4.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE S612",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V3.0 and < V4.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE S623",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V3.0 and < V4.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE S627-2M",
          "versions": [
            {
              "status": "affected",
              "version": "All versions >= V3.0 and < V4.1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-02-11T16:15:14.587",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). Los paquetes especialmente diseñados enviados hacia el puerto 443/tcp de los dispositivos afectados podrían causar una condición de Denegación de Servicio del servidor web"
    }
  ],
  "lastModified": "2026-06-17T02:17:25.623",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "253D14CB-CD7E-40B0-8F3F-1D35FDC46658",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "340031C6-BD77-4601-AA35-4B3A85729576",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0E518E7C-EDF2-4E6A-8C9F-7623FC66CC3F",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5FA5FF74-3117-48F0-8AE6-658B180B7FF0",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}