« Back to list

CVE-2019-13534

Status: ModifiedHigh (7.2)—

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (4)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2019-13534",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Philips IntelliVue WLAN, portable patient monitors",
          "versions": [
            {
              "status": "affected",
              "version": "WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-09-12T20:15:11.727",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code."
    },
    {
      "lang": "es",
      "value": "Philips IntelliVue WLAN, monitores portátiles de pacientes, WLAN Versión A, Firmware A.03.09, WLAN Versión A, Firmware A.03.09, Número de Parte: M8096-67501, WLAN Versión B, Firmware A.01.09, Número de Parte: N/A (Reemplazado por Versión C) y WLAN Versión B, Firmware A.01.09, Número de Parte: N/A (Reemplazado por Versión C). El producto descarga el código fuente o un ejecutable desde una ubicación remota y ejecuta el código sin comprobar suficientemente el origen y la integridad del código."
    }
  ],
  "lastModified": "2026-06-17T02:16:55.693",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp_monitors_mp20-mp90_firmware:a.03.09:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5C10276D-AC93-4376-BC00-A4CFE87494CF"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:m80010a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4C22BF69-D587-47B4-B0AD-1F88746C297F"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8001a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4B64EF43-8C1F-4C71-B848-15F9F02CAFBB"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8002a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "394F4FB4-388D-449A-9D29-B8DB22A11367"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8003a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C2BBB610-D79C-4932-A9CD-BFC9D7F9E0DB"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8004a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BBC4F6D8-7DDA-46E6-8AF9-A1D8F215B471"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8005a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9D1DB684-8836-4ECE-8AA4-984AA02C4E11"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8007a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B0D22C8E-39B7-4E4A-A2F2-A9D85452B875"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8008a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "425500E7-0145-431B-8166-3A4B800610D3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp_monitors_mp5\\/5sc_firmware:a.03.09:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9495245E-7A86-49FE-8E77-1756462D4C24"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:m8105a:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8811CCC6-2F16-4B40-B9B5-264A64710E04"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8105as:a:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "12EF5736-5006-4E87-B948-D49A6F77734C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp_monitors_mp2\\/x2_firmware:a01.09:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5EB4C067-28A5-4AAF-82A7-70CEDF5154A4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:m3002a:b:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "653231C1-C789-4165-8172-793AB40593ED"
            },
            {
              "criteria": "cpe:2.3:h:philips:m8102a:b:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9857800B-24BC-4B23-945F-A97E71ADDCBA"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp_monitors_mx800\\/700\\/600_firmware:a.01.09:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D4D1328C-7865-4403-AC0B-7185FEF780DE"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:865240:b:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3D44F758-0A4F-4D99-A27A-634D235A25E1"
            },
            {
              "criteria": "cpe:2.3:h:philips:865241:b:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "11FF0B81-1411-4213-8AA0-1C85B7840AA1"
            },
            {
              "criteria": "cpe:2.3:h:philips:865242:b:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7EB51EB9-5E7E-42DA-B05E-A9189CF8A734"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}