« Volver al listado

CVE-2019-13379

Estado: ModificadaAlta (8.8)—

On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-13379",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-07-07T16:15:10.227",
  "references": [
    {
      "url": "https://jordonlovik.wordpress.com/2019/07/06/roomalert-by-avtech-critical-vulnerability-disclosure/",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0010",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.youtube.com/watch?v=X1PY7kMFkVg",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://jordonlovik.wordpress.com/2019/07/06/roomalert-by-avtech-critical-vulnerability-disclosure/",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0010",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.youtube.com/watch?v=X1PY7kMFkVg",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-668"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in."
    },
    {
      "lang": "es",
      "value": "En los dispositivos Room Alert 3E anteriores a versión 2.2.5 de AVTECH, un atacante con acceso a la interfaz web del dispositivo puede escalar los privilegios desde un usuario no identificado hacia un administrador mediante la ejecución de un reinicio cmd.cgi?action=ResetDefaults&src=RA y usando las credenciales por defecto para ingresar ."
    }
  ],
  "lastModified": "2026-06-17T02:16:40.297",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:avtech:room_alert_3e_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "63D02D4E-8E87-4D42-A3B8-319F500075FE",
              "versionEndExcluding": "2.2.5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:avtech:room_alert_3e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "40D6C448-E38B-4650-9282-789E86AC3D98"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}