« Volver al listado

CVE-2019-12612

Estado: ModificadaAlta (7.8)—

An issue was discovered in Bitdefender BOX firmware versions before 2.1.37.37-34 that allows an attacker to pass arbitrary code to the BOX appliance via the web API. In order to exploit this vulnerability, an attacker needs presence in Bitdefender BOX setup network and Bitdefender BOX be in setup mode.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-12612",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.2,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-10-31T17:15:10.227",
  "references": [
    {
      "url": "https://www.bitdefender.com/support/security-advisories/bitdefender-box-local-code-execution/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.bitdefender.com/support/security-advisories/bitdefender-box-local-code-execution/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Bitdefender BOX firmware versions before 2.1.37.37-34 that allows an attacker to pass arbitrary code to the BOX appliance via the web API. In order to exploit this vulnerability, an attacker needs presence in Bitdefender BOX setup network and Bitdefender BOX be in setup mode."
    },
    {
      "lang": "es",
      "value": "Se detectó un problema en Bitdefender BOX en las versiones de firmware anteriores a 2.1.37.37-34, lo que permite a un atacante pasar código arbitrario hacia el dispositivo BOX por medio de la API web. Para explotar esta vulnerabilidad, un atacante necesita presencia en la red de configuración de Bitdefender BOX y que Bitdefender BOX este en modo de configuración."
    }
  ],
  "lastModified": "2026-06-17T02:14:57.087",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bitdefender:box_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6EAC4F45-4E09-4782-B6D2-28B857F5A59C",
              "versionEndExcluding": "2.1.37.37-34"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bitdefender:box:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "51BC3E15-5AA6-4353-BA9D-C5FB975544C2"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}