CVE-2019-11892
Estado: ModificadaAlta (8)—
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.03%
- Percentil entre todas las CVEs puntuadas: 62
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-284
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-11892",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "psirt@bosch.com",
"affectedData": [
{
"vendor": "Bosch",
"product": "Smart Home Controller",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "9.8.905",
"versionType": "custom"
}
]
}
]
}
],
"published": "2019-05-29T20:29:00.253",
"references": [
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"tags": [
"Vendor Advisory"
],
"source": "psirt@bosch.com"
},
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad potencial de control de acceso inadecuado en el JSON-RPC interfaz de BOSCH Smart Home Controller (SHC) anterior a 9.8.905 que puede dar como resultado una lectura o modificación de la confifuración SHC´s o activación y restauración de las copais de seguridad.Para poder aprovechar la vulnerabilidad, el adversario necesita haber emparejado con éxito una aplicación o servicio, lo que requiere la interacción del usuario."
}
],
"lastModified": "2026-06-17T02:13:49.277",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:smart_home_controller_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "208D1A1D-4982-457F-A29B-0BE857355DC5",
"versionEndExcluding": "9.8.905"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:smart_home_controller:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "83665608-FC8C-4C92-9DAD-A025433DDD33"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@bosch.com"
}