CVE-2019-11891
Estado: ModificadaAlta (8)—
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.54%
- Percentil entre todas las CVEs puntuadas: 43
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-266
- CWE-269
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-11891",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.4,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.1
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "psirt@bosch.com",
"affectedData": [
{
"vendor": "Bosch",
"product": "Smart Home Controller",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "9.8.905",
"versionType": "custom"
}
]
}
]
}
],
"published": "2019-05-29T20:29:00.207",
"references": [
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"tags": [
"Vendor Advisory"
],
"source": "psirt@bosch.com"
},
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"description": [
{
"lang": "en",
"value": "CWE-266"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad potencial de asignación de privilegios de asignación de privilegios incorrrecta en el mecanismo de emparajamiento de las aplicaciones del controlador Bosch Smart Home (SHC) anteriores a 9.8.905 que puede conllevar a privilegios elevados de la elección del adversario. Para aprovechar la vulnerabilidad el adversario neceista acceso físico al SHC durante el ataque."
}
],
"lastModified": "2026-06-17T02:13:49.130",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:smart_home_controller_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "208D1A1D-4982-457F-A29B-0BE857355DC5",
"versionEndExcluding": "9.8.905"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:smart_home_controller:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "83665608-FC8C-4C92-9DAD-A025433DDD33"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@bosch.com"
}