CVE-2019-11603
Estado: ModificadaAlta (7.5)—
A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.42%
- Percentil entre todas las CVEs puntuadas: 84
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-11603",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-08-21T20:15:12.570",
"references": [
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A HTTP Traversal Attack in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.0.2 allows remote attackers to read files outside the http root."
},
{
"lang": "es",
"value": "Un ataque transversal HTTP en versiones anteriores que ProSyst mBS SDK 8.2.6 y Bosch IoT Gateway Software 9.0.2 permite a los atacantes remotos leer archivos fuera de la raíz http."
}
],
"lastModified": "2026-06-17T02:13:15.210",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bosch:iot_gateway_software:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C0430B96-0668-4E4F-91CF-308BC33734C7",
"versionEndExcluding": "9.0.2"
},
{
"criteria": "cpe:2.3:a:bosch:prosyst_mbs_sdk:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F04B3C5D-FCB9-48F5-BFA0-3673BCF23D8D",
"versionEndExcluding": "8.2.6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}