CVE-2019-11167
Estado: ModificadaAlta (7.8)—
Improper file permission in software installer for Intel(R) Smart Connect Technology for Intel(R) NUC may allow an authenticated user to potentially enable escalation of privilege via local access.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-732
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-11167",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "Intel®",
"product": "Smart Connect Technology for Intel® NUC Advisory",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
]
}
],
"published": "2019-10-11T18:15:11.177",
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00286.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00286.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper file permission in software installer for Intel(R) Smart Connect Technology for Intel(R) NUC may allow an authenticated user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "Un permiso de archivo inapropiado en el instalador de software para Intel® Smart Connect Technology para Intel® NUC puede permitir a un usuario autenticado habilitar potencialmente una escalada de privilegios por medio del acceso local."
}
],
"lastModified": "2026-06-17T02:12:27.823",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:smart_connect_technology:-:*:*:*:*:*:nuc:*",
"vulnerable": true,
"matchCriteriaId": "39294E5A-C7E8-4C18-8273-863D1DAF9E8E"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}