CVE-2019-10981
Estado: ModificadaAlta (7.8)—
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.38%
- Percentil entre todas las CVEs puntuadas: 30
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-522
- CWE-522
Referencias
- http://www.securityfocus.com/bid/108543
- https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01
- https://security.cse.iitk.ac.in/responsible-disclosure
- https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf
- http://www.securityfocus.com/bid/108543
- https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01
- https://security.cse.iitk.ac.in/responsible-disclosure
- https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-10981",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "AVEVA",
"product": "AVEVA Vijeo Citect and CitectSCADA",
"versions": [
{
"status": "affected",
"version": "Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40"
}
]
}
]
}
],
"published": "2019-05-31T21:29:02.267",
"references": [
{
"url": "http://www.securityfocus.com/bid/108543",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://security.cse.iitk.ac.in/responsible-disclosure",
"tags": [
"Third Party Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "http://www.securityfocus.com/bid/108543",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://security.cse.iitk.ac.in/responsible-disclosure",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
},
{
"lang": "es",
"value": "En los sistemas Vijeo Citect versiones 7.30 y 7.40, y CitectSCADA versiones 7.30 y 7.40, ha sido identificada na vulnerabilidad que puede permitir el acceso a las credenciales de usuario de Citect por parte de un usuario local identificado"
}
],
"lastModified": "2026-06-17T02:12:03.083",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada:7.30:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "718E137A-94A1-46E2-B81E-D0812BC4894E"
},
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada:7.40:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A21DF1A9-A957-419F-A84B-EB73F1FB15FA"
},
{
"criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.30:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A005118C-AB06-4F8C-AED5-FB186534C48D"
},
{
"criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.40:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7DCB46CA-EBF8-4318-9671-B5A5D6DED3CE"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}