« Volver al listado

CVE-2019-10331

Estado: ModificadaMedia (4.3)—

A cross-site request forgery vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed attackers to connect to an attacker-specified URL using attacker-specified credentials.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-10331",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "jenkinsci-cert@googlegroups.com",
      "affectedData": [
        {
          "vendor": "Jenkins project",
          "product": "Jenkins ElectricFlow Plugin",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.5 and earlier"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-06-11T14:29:00.697",
  "references": [
    {
      "url": "http://www.openwall.com/lists/oss-security/2019/06/11/1",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "jenkinsci-cert@googlegroups.com"
    },
    {
      "url": "http://www.securityfocus.com/bid/108747",
      "source": "jenkinsci-cert@googlegroups.com"
    },
    {
      "url": "https://jenkins.io/security/advisory/2019-06-11/#SECURITY-1410%20%281%29",
      "source": "jenkinsci-cert@googlegroups.com"
    },
    {
      "url": "http://www.openwall.com/lists/oss-security/2019/06/11/1",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/108747",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://jenkins.io/security/advisory/2019-06-11/#SECURITY-1410%20%281%29",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A cross-site request forgery vulnerability in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed attackers to connect to an attacker-specified URL using attacker-specified credentials."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de tipo cross-site request forgery en el Plugin ElectricFlow de Jenkins versión 1.1.5 y anteriores, en Configuration#doTestConnection permitió a los atacantes conectarse a una URL especificada por el agresor utilizando credenciales especificadas por él mismo."
    }
  ],
  "lastModified": "2026-06-17T02:10:43.877",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jenkins:electricflow:*:*:*:*:*:jenkins:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FC1DBB7B-0A05-4FA8-9CB2-775193ECC96E",
              "versionEndIncluding": "1.1.5"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "jenkinsci-cert@googlegroups.com"
}