CVE-2019-0106
Estado: ModificadaMedia (6.7)—
Insufficient run protection in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable escalation of privilege via local access.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.47%
- Percentil entre todas las CVEs puntuadas: 38
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- NVD-CWE-noinfo
Referencias
- http://www.securityfocus.com/bid/107069
- https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01
- https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html
- http://www.securityfocus.com/bid/107069
- https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01
- https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-0106",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-02-18T17:29:00.580",
"references": [
{
"url": "http://www.securityfocus.com/bid/107069",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "secure@intel.com"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "http://www.securityfocus.com/bid/107069",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient run protection in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "Una protección de ejecución insuficiente en una rutina de instalación para Intel ® Data Center Manager SDK, en versiones anteriores a la 5.0.2, podría permitir a un usuario privilegiado habilitar un escalado de privilegios mediante un acceso local."
}
],
"lastModified": "2026-06-17T02:07:42.577",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A9CFEB9D-54FC-4F61-851D-37D4CACCC09F",
"versionEndExcluding": "5.0.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}