CVE-2018-8902
Estado: ModificadaMedia (6.5)—
An issue was discovered in Ivanti Avalanche for all versions between 5.3 and 6.2. The impacted products used a single shared key encryption model to encrypt data. A user with access to system databases can use the discovered key to access potentially confidential stored data, which may include Wi-Fi passwords. This discovered key can be used for all instances of the product.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.74%
- Percentil entre todas las CVEs puntuadas: 77
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-287
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-8902",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"authentication": "SINGLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-06-29T15:29:00.443",
"references": [
{
"url": "https://community.ivanti.com/docs/DOC-68406",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://community.ivanti.com/docs/DOC-68406",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Ivanti Avalanche for all versions between 5.3 and 6.2. The impacted products used a single shared key encryption model to encrypt data. A user with access to system databases can use the discovered key to access potentially confidential stored data, which may include Wi-Fi passwords. This discovered key can be used for all instances of the product."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en Ivanti Avalanche para todas las versiones entre la 5.3 y la 6.2. Los productos afectados utilizaron un único modelo de cifrado de clave compartida para cifrar los datos. Un usuario con acceso a las bases de datos del sistema puede utilizar la clave descubierta para acceder a datos almacenados potencialmente confidenciales,pudiendo incluir contraseñas Wi-Fi. Esta clave descubierta se puede utilizar para todas las instancias del producto."
}
],
"lastModified": "2026-06-17T02:05:37.140",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ivanti:avalanche:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6437AEEE-FD64-46CB-BD1A-B59C8ABB9774",
"versionEndIncluding": "6.2",
"versionStartIncluding": "5.3"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}