« Back to list

CVE-2018-7793

Status: ModifiedHigh (8.7)—

A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (4)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2018-7793",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 8.7,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 2
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric SE",
          "product": "FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.)",
          "versions": [
            {
              "status": "affected",
              "version": "FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-12-24T16:29:00.640",
  "references": [
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de gestión de credenciales en FoxView HMI SCADA (todas las versiones de Foxboro DCS, Foxboro Evo e IA Series anteriores a Foxboro DCS Control Core Services 9.4 (CCS 9.4) y FoxView 10.5.) que podría permitir la divulgación, modificación o interrupción no autorizada del servicio cuando se modifica la contraseña sin permiso."
    }
  ],
  "lastModified": "2026-06-17T02:03:44.517",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:foxboro_dcs:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DBD743B7-7CED-46B6-9ECD-0C082BD8F5DB",
              "versionEndExcluding": "ccs_9.4"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:foxboro_evo:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FE0621CA-DEB5-46C6-8F6C-EABA5DA04DFE",
              "versionEndExcluding": "ccs_9.4"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:foxview:10.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "875225C7-6546-41BB-96DB-450F5C99494E"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:ia_series:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9EDC2A27-E072-4D61-9A35-714571A3E9A1",
              "versionEndExcluding": "ccs_9.4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}