CVE-2018-7778
Estado: ModificadaCrítica (9.8)—
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.08%
- Percentil entre todas las CVEs puntuadas: 81
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-7778",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric SE",
"product": "Evlink Charging Station",
"versions": [
{
"status": "affected",
"version": "Web Interface, all versions prior to v3.2.0-12_v1"
}
]
}
]
}
],
"published": "2018-07-03T14:29:01.210",
"references": [
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users."
},
{
"lang": "es",
"value": "En las versiones anteriores a la v3.2.0-12_v1 de Schneider Electric Evlink Charging Station, la interfaz web tiene un problema que puede permitir que un atacante remoto obtenga privilegios administrativos sin autenticar correctamente a los usuarios remotos."
}
],
"lastModified": "2026-06-17T02:03:42.380",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:evlink_charging_station_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0B2C5810-2436-4AE7-8B3E-5D28F91C098E",
"versionEndExcluding": "3.2.0-12_v1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:evlink_charging_station:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D7BA4983-91EA-4E08-865E-1F4B3CCF28F8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}