CVE-2018-7774
Estado: ModificadaAlta (8.8)—
The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.97%
- Percentil entre todas las CVEs puntuadas: 61
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-7774",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric SE",
"product": "U.Motion",
"versions": [
{
"status": "affected",
"version": "U.motion Builder Software, all versions prior to v1.3.4"
}
]
}
]
}
],
"published": "2018-07-03T14:29:01.007",
"references": [
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-095-01/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-095-01/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en el procesamiento de localize.php en el software de Schneider Electric U.motion Builder en versiones anteriores a la v1.3.4. La consulta de la base de datos SQLite subyacente está sujeta a una inyección SQL en el parámetro de entrada username."
}
],
"lastModified": "2026-06-17T02:03:42.020",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3DF1942-84D5-480C-96AA-3B03B58D43B5",
"versionEndExcluding": "1.3.4"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}