Estado: ModificadaAlta (7.2)—
A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that would not be logged. Workaround: None. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 4.27%
- Percentil entre todas las CVEs puntuadas: 91
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-78
Referencias
- http://www.securityfocus.com/bid/108374
- https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf
- https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt
- http://www.securityfocus.com/bid/108374
- https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf
- https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-7082",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "security-alert@hpe.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Aruba Instant (IAP)",
"versions": [
{
"status": "affected",
"version": "Aruba Instant 4.x prior to 6.4.4.8 - 4.2.4.12 Aruba Instant 6.5.x prior to 6.5.4.11 Aruba Instant 8.3.x prior to 8.3.0.6 Aruba Instant 8.4.x prior to 8.4.0.1"
}
]
}
]
}
],
"published": "2019-05-10T17:29:01.110",
"references": [
{
"url": "http://www.securityfocus.com/bid/108374",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"source": "security-alert@hpe.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf",
"tags": [
"Third Party Advisory"
],
"source": "security-alert@hpe.com"
},
{
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt",
"tags": [
"Vendor Advisory"
],
"source": "security-alert@hpe.com"
},
{
"url": "http://www.securityfocus.com/bid/108374",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that would not be logged. Workaround: None. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0"
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyección de comandos está presente en Aruba Instant que permite a un usuario administrativo autenticado realizar comandos arbitrarios en el sistema operativo subyacente. Un administrador malicioso podría usar esta habilidad para instalar backdoors o cambiar la configuración del sistema de una manera que no quede registro. Solución: ninguna. Resolución: corregida en Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6 y 8.4.0.0"
}
],
"lastModified": "2026-06-17T02:02:38.517",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EC1A7F0E-2967-4FFD-AF10-993F73B29C79",
"versionEndExcluding": "4.2.4.12",
"versionStartIncluding": "4.0"
},
{
"criteria": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4A8C11A-80E4-4927-8794-92AED47956E7",
"versionEndExcluding": "6.5.4.11",
"versionStartIncluding": "6.5.0"
},
{
"criteria": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B3211B36-0F4B-480D-AC85-D481D6C8BB67",
"versionEndExcluding": "8.3.0.6",
"versionStartIncluding": "8.3.0.0"
},
{
"criteria": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E269D3DC-0DA7-4FC6-8591-E4B324F9F482",
"versionEndExcluding": "8.4.0.1",
"versionStartIncluding": "8.4.0"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4AB6855-E124-4F3C-9993-647B4AB1ACBF",
"versionEndExcluding": "8.4.0.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FBC30055-239F-4BB1-B2D1-E5E35F0D8911"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "security-alert@hpe.com"
}