« Back to list

CVE-2018-7075

Status: ModifiedMedium (6.1)—

A remote cross-site scripting (XSS) vulnerability was identified in HPE Intelligent Management Center (iMC) PLAT version v7.3 (E0506). The vulnerability is fixed in Intelligent Management Center PLAT 7.3 E0605P04 or subsequent version.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2018-7075",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security-alert@hpe.com",
      "affectedData": [
        {
          "vendor": "Hewlett Packard Enterprise",
          "product": "HPE Intelligent Management Center (IMC)",
          "versions": [
            {
              "status": "affected",
              "version": "v7.3 (E0506)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-08-06T20:29:02.117",
  "references": [
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03863en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security-alert@hpe.com"
    },
    {
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03863en_us",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote cross-site scripting (XSS) vulnerability was identified in HPE Intelligent Management Center (iMC) PLAT version v7.3 (E0506). The vulnerability is fixed in Intelligent Management Center PLAT 7.3 E0605P04 or subsequent version."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad de Cross-Site Scripting (XSS) remoto en HPE Intelligent Management Center (iMC) PLAT en versiones 7.3 (E0506). La vulnerabilidad ha sido resuelta en Intelligent Management Center PLAT 7.3 E0605P04 o siguientes."
    }
  ],
  "lastModified": "2026-06-17T02:02:37.807",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:hp:intelligent_management_center:7.3:e0506:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "394C1F2C-5852-4A99-82AD-1B874E8F4164"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com"
}