« Volver al listado

CVE-2018-3602

Estado: ModificadaAlta (8.8)—

An AdHocQuery_Processor SQL injection remote code execution (RCE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to execute arbitrary code on vulnerable installations.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-3602",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": true,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Trend Micro",
          "product": "Trend Micro Control Manager",
          "versions": [
            {
              "status": "affected",
              "version": "6.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2018-02-09T22:29:00.800",
  "references": [
    {
      "url": "https://success.trendmicro.com/solution/1119158",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "security@trendmicro.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-18-068/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "security@trendmicro.com"
    },
    {
      "url": "https://success.trendmicro.com/solution/1119158",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-18-068/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An AdHocQuery_Processor SQL injection remote code execution (RCE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to execute arbitrary code on vulnerable installations."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de ejecución remota de código (RCE) por inyección SQL en AdHocQuery_Processor en Trend Micro Control Manager 6.0 podría permitir que un atacante remoto ejecute código arbitrario en instalaciones vulnerables."
    }
  ],
  "lastModified": "2026-06-17T01:57:32.260",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2F7E3779-69E4-46AB-94E3-4A81E35A5194"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security@trendmicro.com"
}