CVE-2018-21150
Estado: ModificadaMedia (6.8)—
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.59%
- Percentil entre todas las CVEs puntuadas: 47
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (11)
CWE
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-21150",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.2,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 5.1,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 6.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2020-04-22T20:15:11.107",
"references": [
{
"url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://kb.netgear.com/000059483/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Gateways-and-Routers-PSV-2017-3155",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.42, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR están afectados por un desbordamiento del búfer en la región stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 en versiones anteriores a la 1.0.1.34, DM200 en versiones anteriores a la 1.0.0.50, R6100 en versiones anteriores a la 1.0.1.22, R7500 en versiones anteriores a la 1.0.0.122, R7500v2 en versiones anteriores a la 1.0.3.26, R7800 en versiones anteriores a la 1.0.2.42, R8900 en versiones anteriores a la 1. 0.3.10, R9000 en versiones anteriores a la 1.0.3.10, WNDR3700v4 en versiones anteriores a la 1.0.2.96, WNDR4300 en versiones anteriores a la 1.0.2.98, WNDR4300v2 en versiones anteriores a la 1.0.0.54, WNDR4500v3 en versiones anteriores a la 1.0.0.54, y WNR2000v5 en versiones anteriores a la 1.0.0.64."
}
],
"lastModified": "2026-06-17T01:54:14.430",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EB24F17D-A9A8-4EF9-BF53-580395D60EFC",
"versionEndExcluding": "1.0.1.34"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FDF86215-ABBD-43EA-B7DE-D3038F4449C6",
"versionEndExcluding": "1.0.0.50"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7FFFF63B-46C8-49BF-8494-BB3322F14594",
"versionEndExcluding": "1.0.1.22"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5F99E4DD-50CB-4B06-BDAF-DD56FF0E90CF",
"versionEndExcluding": "1.0.0.122"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9ACBF492-1315-46CF-8297-E239DDB14B6B",
"versionEndExcluding": "1.0.3.26"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D9D351BB-5034-4771-96BB-F143951CE5D5",
"versionEndExcluding": "1.0.2.42"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "610C6DB8-E11E-4EAE-A16F-189283F70B26",
"versionEndExcluding": "1.0.3.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EEFCBDB9-47D0-40EF-9428-FF714763BC12",
"versionEndExcluding": "1.0.3.10"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FAF6A089-4E7D-43D1-AF1F-01A7A592115E",
"versionEndExcluding": "1.0.2.96"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EF96C0EB-8CB6-4C86-A9A2-A4C7AF58C97F",
"versionEndExcluding": "1.0.2.98"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CC5A295B-77E9-4F8B-B523-56C7A1472AD9",
"versionEndExcluding": "1.0.0.54"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A5B27DF7-FA36-4A0E-A7B0-0D29BE9434BE",
"versionEndExcluding": "1.0.0.54"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "124ABC0A-DD68-4540-AAC2-C4E87CDC91A7",
"versionEndExcluding": "1.0.0.64"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}