Estado: ModificadaCrítica (9.8)—

A buffer overflow vulnerability was discovered in the OpenPLC controller, in the OpenPLC_v2 and OpenPLC_v3 versions. It occurs in the modbus.cpp mapUnusedIO() function, which can cause a runtime crash of the PLC or possibly have unspecified other impact.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2018-20818",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-04-22T11:29:01.970",
  "references": [
    {
      "url": "https://arxiv.org/pdf/1809.07477",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://arxiv.org/pdf/1809.07477",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A buffer overflow vulnerability was discovered in the OpenPLC controller, in the OpenPLC_v2 and OpenPLC_v3 versions. It occurs in the modbus.cpp mapUnusedIO() function, which can cause a runtime crash of the PLC or possibly have unspecified other impact."
    },
    {
      "lang": "es",
      "value": "Fue encontrada una vulnerabilidad de desbordamiento de búfer en el controlador OpenPLC, en las versiones OpenPLC_v2 y OpenPLC_v3. Se produce en la función de mapUnusedIO() Modbus.cpp, que puede provocar un bloqueo en tiempo de ejecución del PLC o, posiblemente, tener otro impacto no especificado."
    }
  ],
  "lastModified": "2026-06-17T01:53:32.400",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:openplcproject:openplc_v2_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A9D03A78-0590-471D-8C3A-A620F0C46649"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:openplcproject:openplc_v2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6100B866-B033-4EAA-8172-41C165424238"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:openplcproject:openplc_v3_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7624BE59-886B-421D-96CC-105F185AE070"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:openplcproject:openplc_v3:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6861E863-E6AC-4BFB-8CDE-2328A045540D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}